High Resolution Spectrometer UV/VIS - getSpec 3648



Request for information



  • High resolution - 3648 pixel detector
  • USB 2.0 interface – 480 Mbps
  • Data transfer speed: 3.7 ms/Scan
  • Optional: Bluetooth-communication
  • Saving on internal SD RAM-card

The new getSpec-3648 spectrometers were developed for fiber optic spectroscopy applications in the UV/VIS and shortwave NIR range. These instruments are suited for laboratory, industrial, biotechnology, medical and environmental (mobile) use. The spectrometers are based on a revolutionary electronics design with a 14-bit multi-channel AD converter, on-board microprocessor and USB 2.0 high speed interface. The detector of the spectrometer is a 3648 pixel, high sensitive CCD SONY detector. The optical bench has 75 mm focal length and can be used for measurements from 200 – 1100 nm, with high spectral resolution of up to 0,025 nm FWHM. This spectrometer can be configured as a multi channel instrument, taking spectra from up to 8 channels simultaneously with a minimal integration time of 10 µs. 14 (2 in, 12 out) programmable digital IO ports can be used for external triggering, control of external light sources, shutters or process applications.


The spectrometer has a fiber optic entrance connector (Standard SMA, others possible), collimating and focusing mirror and diffractional grating. A choice of 12 different gratings with different dispersion and blaze angles enable applications in the 200-1100nm range.
The new getSpec-3648 has an USB 2.0 interface with fast data sampling of 270 spectra per second and data transfer in 3.7 msec and supports analog in- and outputs as well. Optional Bluetooth (-BT) communication and an SDRAM card for on-board saving of spectra can be added. The getSpec-3648-USB 2.0 runs on USB power and comes with getSoft-basic, a complete manual and USB interface cable.


Technical Specification:
getSpec 3648
Optical Bench Symmetrical Czerny-Turner, 75 mm focal length
Wavelength range 200-1100 nm
Resolution 0.025 –20 nm, depending on configuration (see table)
Stray light < 0.1%
Sensitivity (halogen light source, 8 µm fiber) 12000 counts @ 2 ms int. time
Detector CCD linear array, 3648 pixels
Signal/Noise 300:1
AD converter 14 bit, 1 MHz
Integration time 10 µsec – 10 min
Interface USB 2.0 high Speed, 480 Mbps
RS-232, baudrate 115.200 bps
Sample speed with on-board averaging3,7 ms / scan
Data transfer speed 3,7 ms / scan
Digital IO HD-26 connector, 2 Analog in, 2 Analog out, 3 Digital in, 12 Digital out, trigger, synchronization
Status LED Green = power, yellow = scan
Power supply Default USB power, 440 mA
Or with SPU2 external 12VDC, 440 mA
Resolution3648 Pixel
CommunicationBluetooth (optional)
Storageinternal SD-RAM card
Dimensions175 x 110 x 44 mm (1 channel)



Grating Selection Table
UseUseable RangeSpectral Range (nm) Lines/mm Blaze (nm)Code
UV/VIS/NIR 200 - 1100 900 300 300 UA
VIS/VIS200 - 850520600 250UB
UV 250 - 750 250 - 2201200250UC
UV 200 - 650 165 - 1451800250 UD
UV 200 - 580 115 - 70 2400250 UE
UV 220 - 400 75 - 50 3600250 UF
UV/VIS 250 - 580 520600370BB
VIS/NIR300 - 1100800300500VA
VIS360 - 1100 500 600 500 VB
VIS 300 - 800 250 - 2001200 500 VC
VIS 350 - 750 145 - 1001800 500 VD
NIR 500 - 1050 500 600 750 NB
NIR 500 - 1050 220 - 1501200 750 NC
NIR 600 - 1100 500 300 1000 IA
NIR600 - 11005006001000IB



Spectral Resolution (FWHM) Table
Slit Size(µm)
Grating(Lines/mm)1025 50 100 200 500
3000.5 1.42.44.38.020.0
6000.25 0.71.2 2.14.110.0
12000.07-0.130.2-0.30.4-0.60.7-1.01.4-2.03.3-4.8
18000.05-0.080.12-0.210.2-0.360.4-0.70.7-1.41.7-3.3
24000.04-0.070.08-0.150.14-0.250.3-.050.5-0.91.2-2.2




System Overview
Spectrometer
Wavelength Range
Slit Size
Optical Resolution
Application
Code
(nm)
(µm)
(nm, FWHM)
getSpec-3648-UV
190 - 340 nm
10
0,05
High resolution application in UV-range
UD-10
getSpec-3648-UV
190 - 340 nm
50
0,3
UV Irradiance measurement
UD-50
getSpec-3648-UV/VIS
200 - 720 nm
10
0,25
UV/VIS Irradiance measurement
BB-10
getSpec-3648-UV/VIS
200 - 720 nm
25
0,7
Thin film application
BB-25
getSpec-3648-UV/VIS
200 - 720 nm
200
4,1
Fluorescence
BB-200
getSpec-3648-VIS
360 - 600 nm
10
0,07
Transmission of filters
VC-10
getSpec-3648-VIS
360 - 600 nm
25
0,8
LED analysis
VB-25
getSpec-3648-VIS/NIR
360 - 860 nm
10
0,25
Absorption measurement of dyes
VB-10
getSpec-3648-VIS/NIR
360 - 860 nm
25
2,1
Standard color measurement
BB-100
getSpec-3648-VIS/NIR
360 - 860 nm
100
2,1
Titration
VB-100
getSpec3648-UV/VIS/NIR
300 - 1100 nm
200
8
Fluorescence
VA-200
getSpec-3648-UV/VIS/NIR
200 - 1100 nm
10
0,5
allround, laser analysis, plasma
UA-10
getSpec-3648-UV/VIS/NIR
200 - 1100 nm
25
1,4
allround, transmission
UA-25
getSpec-3648-UV/VIS/NIR
200 - 1100 nm
50
2,1
allround, reflection measurement
UA-50
getSpec-3648-UV/VIS/NIR
200 - 1100 nm
100
4,3
allround, reflection measurement with integrating spheres
UA-100